Why sometimes the air volume of compressor is reduced after maintenance?
There are many reasons for the reduction of air compressor production capacity. However, for the air compressor which has just been overhauled, the air volume often decreases when it is initially started. The main reasons are as follows
1) Incorrect maintenance and installation;
2) If the maintenance and installation are correct, the main reason is that the air distribution mechanism (the whole set of devices controlling the air entering and discharging from the cylinder) and the piston parts have not yet run in well.
After any machine is installed, it must go through certain running in before it can work normally. The same is true of air compressor. For the air compressor without running in after maintenance, its air distribution mechanism and piston parts can not be closely matched. In this way, the suction resistance and gas leakage may be large, and the air volume is naturally smaller.
-
How To Reduce Noise And Reduce Vibration Of Compressor[2020/10/03]
-
Six doubt and answer of air compressor lubricating oil[2020/09/06]
-
Three Fault Analysis And Solutions Of Compressors[2020/12/24]
-
How does the reciprocating compressor valve work?[2020/07/06]
-
How to operate reciprocating comoressor[2020/06/23]
-
Five general knowledge of conductive materials in air compressor maintenance[2020/07/06]
-
How to select oil for compressor--refrigeration compressor lubricating oil[2020/06/29]
-
Reciprocating compressor construction--crankshaft and connect rod[2020/06/23]